A chimney flue is the internal passage that carries smoke, combustion gases or process exhaust from a fireplace, stove, boiler, furnace, generator or industrial process to the outdoor atmosphere. It is the gas-contact path, while the chimney is the complete structure that contains or supports that path. A flue may be a metal pipe, a liner inside a masonry or structural chimney, or the inner passage of a factory-built system. Rainbow recommends matching the flue size, material, wall construction and pressure class to the appliance and operating duty.
The word “flue” is often used loosely for a pipe, liner, duct or entire chimney. That may work in conversation, but drawings and quotations should identify the gas-contact component, structural support and boundary between connecting duct and vertical chimney.
| Term | Engineering meaning | Typical function |
|---|---|---|
| Flue | The passage through which combustion or process gas flows | Contains and conveys the gas |
| Flue liner | The material or system forming the inside surface of the flue | Protects surrounding construction and provides a gas-contact barrier |
| Chimney | The complete vertical structure containing one or more flues | Supports and discharges the flue gas at the required elevation |
| Stack | A common industrial term for a vertical discharge structure or emission point | Releases exhaust or process gas to the atmosphere |
| Flue-gas duct | A connecting passage between equipment, treatment units and the chimney | Transfers gas horizontally or through a routed system |
| Outer shell or windshield | The load-bearing structure around one or more flues | Resists wind, seismic and attachment loads |
The International Fuel Gas Code defines a flue as a passageway within a chimney or vent for gaseous combustion products. It defines a chimney as a primarily vertical structure containing one or more flues and separates the flue liner from the surrounding structure.

A chimney flue contains the exhaust stream and carries it to a defined discharge point. In industrial and commercial systems, it must do this without unacceptable leakage, pressure loss, condensation damage or heat transfer to surrounding construction.
Its main functions are:
Gas containment: it keeps combustion products or process exhaust inside a controlled passage.
Flow control: diameter, height and fittings affect velocity, resistance and draft.
Thermal control: its wall and insulation influence heat loss, surface temperature and condensation risk.
Corrosion protection: the gas-contact material must withstand moisture, acids, chlorides, particles and cleaning conditions.
Safe discharge: it carries gas to the specified outlet elevation.
A flue does not remove pollutants by itself. Scrubbers, filters or other equipment may clean the gas before it enters the chimney.
Chimney flues are used in homes, commercial buildings and industrial plants, but their operating conditions and approval basis differ.
| Application | Typical equipment | Common flue form | Main design concerns |
|---|---|---|---|
| Residential | Fireplace chimney, wood or pellet stove, gas appliance | Masonry liner, rigid or flexible liner, single-wall flue pipe, insulated twin-wall flue | Appliance compatibility, clearances, draft, fire safety and local code |
| Commercial | Heating boilers, water heaters, generators, CHP units | Modular single-wall or double-wall stainless steel flue system | Pressure class, condensate, roof penetration, supports and product listing |
| Industrial | Power boilers, furnaces, kilns, incinerators and process plants | Steel shell, separate steel or FRP liner, multi-flue chimney | Gas chemistry, high flow, thermal movement, corrosion, structural loads and inspection |
A residential chimney and home flue system may use modular parts sized for a stove or fuel. Commercial and industrial systems are more often engineered around equipment data, pressure losses and site interfaces.

The flue is the passage; the liner is the material forming that passage; the chimney is the complete structure; and stack is a broader industrial term that often describes the vertical discharge structure or regulated emission point.
These boundaries can overlap. In a single-wall steel chimney, one shell can contain the gas and carry structural loads. In a concrete chimney with a steel or FRP liner, the concrete windshield carries the loads while the liner forms the flue.
A multi-flue chimney can contain several independent gas passages serving different equipment. Schedules should therefore state both the number of chimneys and flues. The distinction between an industrial chimney and exhaust stack also depends on project context rather than a universal difference in height or material.
A chimney flue provides a continuous flow path to the atmosphere. Gas movement may come from natural draft, a fan, equipment pressure or a combination of them.
Hot flue gas is usually less dense than outdoor air. This creates buoyancy and a pressure difference over the chimney height. Available draft must overcome friction and losses through fittings and terminals.
Boilers, generators and industrial processes may use fans or equipment pressure. Positive-pressure service makes joint design, sealing and leakage testing especially important.
ASHRAE’s chimney design guidance treats diameter as an iterative engineering decision because system resistance changes with diameter. Gas flow, mean temperature, density, velocity, friction and fitting losses must be evaluated together. A simple diameter chosen from the equipment outlet is not automatically the correct chimney flue size.
A complete commercial or industrial flue system may include:
inner flue or gas-contact liner;
outer casing, structural shell, mast or concrete windshield;
insulation or a ventilated air space;
straight sections, elbows, tees, transitions and joints;
expansion joints, sliding supports and guides;
condensate drains and collection points;
inspection doors, test ports and cleaning access;
wall brackets, floor supports, base plates or liner supports;
roof penetrations, flashings, silencers and weather seals;
flue cowl, cap, terminal or discharge nozzle.
Project drawings should mark the system boundary so suppliers quote the same scope.

A single-wall flue pipe uses one gas-carrying metal wall. It may be an appliance connector, internal liner or complete approved system. It is lighter and simpler, but loses heat faster and may have a hot outer surface.
A double-wall or twin-wall flue has an inner wall and outer casing separated by insulation or air. It can reduce heat loss, lower casing temperature and help control condensation. Twin-wall systems are common through or outside buildings. The single-wall and double-wall chimney comparison explains the trade-offs.
A rigid or flexible chimney liner can form a defined passage inside an existing masonry chimney or shaft. Residential renovation projects often use metal liners for a fireplace, gas flue chimney or pellet stove flue. Diameter, material, insulation and connections must follow the appliance instructions, system approval and local requirements.
Tall industrial chimneys often separate the gas path from the structure. A suitable liner runs inside a steel shell, concrete windshield or tower. The liner handles gas exposure while the outer structure resists loads.
A multi-flue chimney contains several liners within one support structure. It saves space but requires coordinated expansion, supports, access and replacement planning.
Flue diameter is selected from a pressure and flow calculation, not from chimney height alone.
Important inputs include:
mass or volumetric gas flow at defined temperature and pressure;
normal, maximum and upset temperatures;
gas composition, moisture and particulate loading;
available draft or allowable equipment backpressure;
chimney height and outlet requirements;
length, elbows, transitions, dampers and silencers;
internal roughness, fouling and part-load operation;
ambient temperature, wind and site elevation.
An undersized flue can create excessive velocity, friction loss and equipment backpressure. An oversized flue may reduce velocity and promote condensation. Final sizing must also account for materials, insulation and supports.
Material depends on the gas touching the wall. Temperature resistance alone is not enough; a material suitable for hot dry gas may perform poorly when acidic condensate forms.
| Material family | Common reason for selection | Key engineering check |
|---|---|---|
| Carbon steel | Structural strength and economical dry service | Corrosion allowance, coating limits and condensation exposure |
| Stainless steel | Corrosion resistance and modular stainless steel flue pipe fabrication | Alloy grade, chlorides, acids, temperature and weld treatment |
| Duplex stainless steel | More demanding chloride or corrosive service | Actual condensate chemistry, fabrication procedure and cost |
| FRP or GRP | Wet and chemically aggressive low-temperature gas | Temperature limit, fire performance, joints and structural support |
| Brick, refractory or specialty lining | High temperature or process-specific protection | Thermal cycling, joint condition, weight and maintenance |
Rainbow engineers flue configuration, liner material, insulation, drainage and supports around project gas data. This matters when the structural shell and liner need different materials or independent movement.
Most flue problems begin with unsuitable construction or a failed joint, drain, support or interface.
Condensation and corrosion: water or acidic vapor condenses when the inner surface falls below the relevant dew point.
Gas leakage: damaged welds, seals, flanges or expansion joints release gas into the annular space or building.
Thermal-expansion damage: restrained movement loads joints, supports, ducts and appliance connections.
Deposit buildup: ash, soot or process solids reduce the clear area and may retain corrosive moisture.
Insulation failure: wet or displaced insulation changes heat loss and can hide external corrosion.
Support or guide failure: liner movement and lateral loads can distort the flue or damage connections.
Vibration and fatigue: flow pulsation, machinery vibration or wind response can affect thin metal components and attachments.
The inspection plan should match the application and risk. Residential systems may require checks for deposits, liner damage, joint condition and appliance compatibility. Commercial and industrial inspections may also include thickness measurement, weld examination, leakage testing, drain checks and inspection of expansion joints and supports. Wet or acidic service needs special attention because condensate can attack the gas-contact surface and surrounding construction.
A useful project RFQ defines the operating duty, route and responsibility boundaries. Provide:
equipment type, quantity, fuel and operating schedule;
gas flow, composition, moisture, particles and corrosive constituents;
normal, design and upset temperatures and pressures;
allowable backpressure or required draft;
route, developed length, offsets, penetrations and outlet elevation;
single-wall, double-wall or separate-liner configuration;
materials, corrosion allowance and insulation requirements;
supports, guides, expansion joints, drains and access openings;
applicable codes, product listings, testing and documentation;
delivery, installation, inspection access and interface responsibilities.
Do not request only “one chimney flue” with a height and diameter. Without pressure class, materials, joints, supports and interfaces, supplier quotations may describe different systems.
No. The flue is the passage that carries exhaust gas, while the chimney is the complete vertical structure containing or supporting one or more flues. In a single-wall metal chimney, the same shell may serve both functions, which is why the terms are sometimes used interchangeably.
Not exactly. The flue is the open gas passage. The flue liner is the material or system that forms its inside surface. A stainless steel tube, brick lining or FRP liner may therefore create the boundary of the flue without being the whole chimney structure.
Yes. A multi-flue chimney can contain several independent liners inside one concrete windshield, steel shell or supporting tower. Each flue may serve different equipment. The design must define supports, thermal movement, separation, access and whether any operating cases affect adjacent liners.
A flue is the gas passage within a chimney or venting system. A flue-gas duct usually connects equipment, fans or treatment units to the vertical chimney. The terms can overlap, so project drawings should define where the duct ends and the chimney flue begins.
No. A single-wall steel chimney can use one shell as both the gas-contact passage and structural component. A separate liner is used when the structural shell needs protection, when several flues share one support structure or when temperature, corrosion and replacement needs favor separated functions.
Insulation reduces heat loss, helps control the outer surface temperature and can keep the inner wall warmer. This may improve draft stability and reduce condensation risk. Insulation does not eliminate condensation during startup, shutdown, low load or intentionally condensing service, so drainage and material selection remain necessary.
Engineers balance gas flow, temperature, density, required velocity, pressure loss, available draft or fan pressure, route resistance and equipment backpressure. Because resistance changes with diameter, sizing is normally iterative. Height, fittings, silencers, simultaneous equipment operation and site conditions also affect the result.
There is no universal best material. Carbon steel, stainless steel, duplex stainless steel, FRP, brick and specialty linings suit different duties. Selection should use normal and upset temperatures, gas and condensate chemistry, pressure, abrasion, cleaning method, structural arrangement and required service life.